STANDARD TESTING
PROCEDURE FOR MEASURING CAP 10 ML
1.0
Objective: The purpose of
this STP is to ensure the compliance of quality of MEASURING
2.0
Scope: To establish the standard testing procedure of MEASURING
10 ml in Pharmaceuticals.
3.0
Procedure:
3.1 Description: Transparent
Measuring Cap 10ml.
3.2 Height: Take 20 no. of measuring caps and measure
the height by vernier caliper at different points and justify the readings are
under limits or not. That should be as per limit specified in specification.
3.3
Average weight: Take 20 no. of Measuring caps and
weigh, obtained value convert in to per caps, it should be under limits.
3.4 Graduation: Measuring caps having mark line of
volume at the points 2.5ml, 5.0ml & 10.0ml. So it should be necessary to
confirm the volume which have shown. Take 2.5ml of water by pipette, pour in
it, and check the marking line. Marking line should be following the volume.
Same exercise done by 5.0ml and 10.0ml capacity.
3.5 Outer Diameter Top: Take 20no. of
measuring caps and measure the top diameter
at different points and justify the variance readings are under limits
or not. That should be as per limit specified in specification.
3.6 Outer Diameter with color: Take 20no. of
measuring caps and measure the
diameter with color at different
points and justify the variance readings are under limits or not. That should
be as per limit specified in specification. (* Outer diameter with color should
be variable)
3.7
Colour shade: Colour shed should be clear transparent.