STP FOR MEASURING CAP 15ML

 

STANDARD TESTING
PROCEDURE FOR MEASURING CAP 15ML

1.0        
Objective: The purpose of
this STP is to ensure the compliance of quality of MEASURING CAP 15 ML.

2.0        
 Scope: To establish the standard testing procedure of MEASURING CAP 15 ml in Pharmaceuticals.

3.0        
Procedure:

3.1  Description: Transparent
Measuring Cap 15ml.

3.2  Height: Take 20no. of measuring caps and measure
the height  by vernier caliper at
different points and justify the readings 
are under limits or not. That should be as per limit specified in
specification.

3.3
 Average weight:  Take 20no. of Measuring caps and
weigh, obtained value convert in to per caps, it should be under limits.

3.4  Graduation: Measuring caps having mark line of
volume at the points 2.5ml, 5.0ml, 10.0ml & 15ml. So it should be necessary
to confirm the volume which have shown. Take 2.5ml of water by pipette, pour in
it, and check the marking line. Marking line should be following the volume.
Same exercise done by 5.0ml, 10ml and 15.0ml capacity.

3.5  Outer Diameter Top: Take 20no. of
measuring caps and measure the top diameter 
at different points and justify the variance readings are under limits
or not. That should be as per limit specified in specification.

3.6  Outer Diameter with color: Take 20no. of
measuring caps and measure the 
diameter  with color at different
points and justify the variance readings are under limits or not. That should
be as per limit specified in specification.

3.7
 Colour shade: Colour shed should be clear transparent.